model parameter |
lab usage |
production usage |
|||||
nti-thl-54w |
nti-thl-243w |
nti-thl-300w |
nti-thl-400w |
nti-thl-720w |
nti-thl-720 nw |
||
working size |
mm |
300×300×600 |
450×450×1200 |
500×500×1200 |
500×500×1600 |
600×600×2000 |
(600-800)×(600-800)×(2000-4000) |
control process |
|
thyristor control |
|||||
heating type |
/ |
resistance heating |
|||||
ht zone capacity |
l |
54 |
243 |
300 |
400 |
720 |
720 n |
loading weight |
g |
ht zone capacity × density (g/cm³)×1000 remark:1l=1000cm³ |
|||||
ultimate vacuum |
pa |
20 |
|||||
if power |
kw |
50 |
105 |
120 |
135 |
189 |
189-500 |
heating zone |
zone |
1 |
3 |
3 |
3 |
3 |
3-6 |
max. working temperature |
℃ |
1600 |
1600 |
1600 |
1600 |
1600 |
1600 |
usual working temperature |
℃ |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
temperature unifomity |
℃ |
±5 |
±5 |
±5 |
±5 |
±5 |
±10 |
working environment |
/ |
vacuum or ar, n2 atmosphere protection( micro positive pressure) |
|
model |
nti-thl-400w |
max.temperature |
1600℃ |
working tem. |
1500℃ |
input voltage |
380v±10%,50hz/60hz |
rated power |
135 kw |
heating area |
3 regions |
ht area size |
540 mm × 540 mm × 1600 mm |
effective heating |
constant tem.area: 500 mm × 500 mm × 1600 mm |
tem.measurement |
tungsten rhenium thermocouple(0℃--1700℃) |
tem.controlling |
shimadne automatic control and high precision adjustable manual control.(accuracy:0.3) |
exhaust way |
smart or manual for choice. |
accuracy |
±0.25% tips:up to infrared probe accuracy grade |
tem.uniformity |
≤±5℃。(after 30min of heating ) |
inner atmospher |
vacuum or ar、n2 atmospher(micro-positive pressure) |
alarm system |
plc smart pre-alarm、alarm and power supply protection |
filtration |
4 grades purifing system |
cooling |
closed inner circulating water cooling/ fbp-2a |
purifing |
argon gas purifier /gya-4c |
ipc |
mcgs (tpc1061ti),(delta)plc |
vacuum system |
side valve type vacuum pumph-150( 1set)、vacuum valve、pipeline and vacuum gauge vacuum degree:20pa
|
total weight |
about 5 tons |