water cooling jacket and air cleaner
model |
st21-sk1 |
st21-sk2 |
st21-sk3 |
|
paramter |
tem.range |
600℃~1800℃ |
800℃~2500℃ |
1000℃~3000℃ |
accuracy |
value measuring ±1% |
|||
repeatability |
value measuring ±0.5% |
|||
resolution |
1℃ |
|||
emissivity |
0.10~1.00 adjustable, step size 0.01 |
|||
response time |
less than 50ms |
|||
tem.meas.mode |
instantaneous value, maximum value and average value |
|||
time interval |
1~30s, step size 1s |
|||
optics parameter |
working band |
1.0um |
||
distance coefficient |
400:1 |
|||
aiming mode |
telescope aiming |
|||
electrical |
power |
24v dc±10% 100ma |
||
output |
4~20ma and rs485 |
|||
environment |
working tem. |
-10℃~ 60℃, cooling with the water to 150℃ |
||
storage tem. |
-20℃~80℃ |
|||
relative humidity |
10%~90%rh non condensing |
|||
physics
|
shell material |
stainless steel |
||
size |
167mm×ф50mm |
|||
weight |
600g |